Keyword search (4,163 papers available)

"Frauscher B" Authored Publications:

Title Authors PubMed ID
1 How vigilance states influence source imaging of physiological brain oscillations: evidence from intracranial EEG Wei X; Afnan J; Avigdor T; von Ellenrieder N; Delaire É; Royer J; Ho A; Minato E; Schiller K; Jaber K; Wang YL; Moye M; Bernhardt BC; Lina JM; Grova C; Frauscher B; 41687693
SOH
2 Personalized biomarkers of multiscale functional alterations in temporal lobe epilepsy Xie K; Sahlas E; Ngo A; Chen J; Arafat T; Royer J; Zhou Y; Rodríguez-Cruces R; Dascal A; Caldairou B; Fadaie F; Barnett A; Audrain S; Larivière S; Caciagli L; Pana R; Weil AG; Grova C; Frauscher B; Schrader DV; Zhang Z; Concha L; Bernasconi A; Bernasconi N; Bernhardt BC; 41258102
SOH
3 Visual Features in Stereo-Electroencephalography to Predict Surgical Outcome: A Multicenter Study Abdallah C; Thomas J; Aron O; Avigdor T; Jaber K; Doležalová I; Mansilla D; Nevalainen P; Parikh P; Singh J; Beniczky S; Kahane P; Minotti L; Chabardes S; Colnat-Coulbois S; Maillard L; Hall J; Dubeau F; Gotman J; Grova C; Frauscher B; 40519108
SOH
4 Spectral and network investigation reveals distinct power and connectivity patterns between phasic and tonic REM sleep Avigdor T; Peter-Derex L; Ho A; Schiller K; Wang Y; Abdallah C; Delaire E; Jaber K; Travnicek V; Grova C; Frauscher B; 40394955
SOH
5 The Awakening Brain is Characterized by a Widespread and Spatiotemporally Heterogeneous Increase in High Frequencies Avigdor T; Ren G; Abdallah C; Dubeau F; Grova C; Frauscher B; 40126936
PERFORM
6 Metrics for evaluation of automatic epileptogenic zone localization in intracranial electrophysiology Hrtonova V; Nejedly P; Travnicek V; Cimbalnik J; Matouskova B; Pail M; Peter-Derex L; Grova C; Gotman J; Halamek J; Jurak P; Brazdil M; Klimes P; Frauscher B; 39608298
SOH
7 NREM sleep brain networks modulate cognitive recovery from sleep deprivation Lee K; Wang Y; Cross NE; Jegou A; Razavipour F; Pomares FB; Perrault AA; Nguyen A; Aydin Ü; Uji M; Abdallah C; Anticevic A; Frauscher B; Benali H; Dang-Vu TT; Grova C; 39005401
PERFORM
8 EEG/MEG source imaging of deep brain activity within the maximum entropy on the mean framework: Simulations and validation in epilepsy Afnan J; Cai Z; Lina JM; Abdallah C; Delaire E; Avigdor T; Ros V; Hedrich T; von Ellenrieder N; Kobayashi E; Frauscher B; Gotman J; Grova C; 38994740
SOH
9 A spatial perturbation framework to validate implantation of the epileptogenic zone Jaber K; Avigdor T; Mansilla D; Ho A; Thomas J; Abdallah C; Chabardes S; Hall J; Minotti L; Kahane P; Grova C; Gotman J; Frauscher B; 38897997
SOH
10 Systematic review of seizure-onset patterns in stereo-electroencephalography: Current state and future directions Abdallah C; Mansilla D; Minato E; Grova C; Beniczky S; Frauscher B; 38733701
PERFORM
11 Consistency of electrical source imaging in presurgical evaluation of epilepsy across different vigilance states Avigdor T; Abdallah C; Afnan J; Cai Z; Rammal S; Grova C; Frauscher B; 38217279
PERFORM
12 Targeted density electrode placement achieves high concordance with traditional high-density EEG for electrical source imaging in epilepsy Horrillo-Maysonnial A; Avigdor T; Abdallah C; Mansilla D; Thomas J; von Ellenrieder N; Royer J; Bernhardt B; Grova C; Gotman J; Frauscher B; 37704552
PERFORM
13 Validating MEG source imaging of resting state oscillatory patterns with an intracranial EEG atlas Afnan J; von Ellenrieder N; Lina JM; Pellegrino G; Arcara G; Cai Z; Hedrich T; Abdallah C; Khajehpour H; Frauscher B; Gotman J; Grova C; 37149236
PERFORM
14 Neurophysiology, Neuropsychology, and Epilepsy, in 2022: Hills We Have Climbed and Hills Ahead. Neurophysiology in epilepsy Frauscher B; Bénar CG; Engel JJ; Grova C; Jacobs J; Kahane P; Wiebe S; Zjilmans M; Dubeau F; 37119580
PERFORM
15 Clinical Yield of Electromagnetic Source Imaging and Hemodynamic Responses in Epilepsy: Validation With Intracerebral Data Abdallah C; Hedrich T; Koupparis A; Afnan J; Hall JA; Gotman J; Dubeau F; von Ellenrieder N; Frauscher B; Kobayashi E; Grova C; 35473762
PERFORM
16 Fast oscillations >40 Hz localize the epileptogenic zone: An electrical source imaging study using high-density electroencephalography. Avigdor T, Abdallah C, von Ellenrieder N, Hedrich T, Rubino A, Lo Russo G, Bernhardt B, Nobili L, Grova C, Frauscher B 33450578
PERFORM

 

Title:Targeted density electrode placement achieves high concordance with traditional high-density EEG for electrical source imaging in epilepsy
Authors:Horrillo-Maysonnial AAvigdor TAbdallah CMansilla DThomas Jvon Ellenrieder NRoyer JBernhardt BGrova CGotman JFrauscher B
Link:https://pubmed.ncbi.nlm.nih.gov/37704552/
DOI:10.1016/j.clinph.2023.08.009
Publication:Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology
Keywords:ESIFociMontagePresurgicalSpike
PMID:37704552 Category: Date Added:2023-09-14
Dept Affiliation: PERFORM
1 Clinical Neurophysiology Section, Clínica Universidad de Navarra, Pamplona, Spain; IdiSNA, Instituto de Investigación Sanitaria de Navarra, Pamplona, Spain; Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada.
2 Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Canada. Electronic address: tamir.avigdor@mail.mcgill.ca.
3 Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Canada. Electronic address: chifaou.abdallah@mail.mcgill.ca.
4 Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada. Electronic address: daniel.mansilla@mail.mcgill.ca.
5 Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada. Electronic address: john.thomas3@mail.mcgill.ca.
6 Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada. Electronic address: nicolas.vonellenrieder@mcgill.ca.
7 Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Multimodal Imaging and Connectome Analysis Laboratory, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada. Electronic address: jessica.royer@mail.mcgill.ca.
8 Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Multimodal Imaging and Connectome Analysis Laboratory, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada. Electronic address: boris.bernhardt@mcgill.ca.
9 Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Canada; Multimodal Functional Imaging Lab, PERFORM Center, Department of Physics, Concordia University, Montreal, QC, Canada. Electronic address: christophe.grova@mcgill.ca.
10 Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada. Electronic address: jean.gotman@mcgill.ca.
11 Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada; Department of Neurology, Duke University Medical Center, Durham, NC, United States; Department of Biomedical Engineering, Duke Pratt School of Engineering, Durham, NC, United States. Electronic address: birgit.frauscher@duke.edu.

Description:

Objective: High-density (HD) electroencephalography (EEG) is increasingly used in presurgical epilepsy evaluation, but it is demanding in time and resources. To overcome these issues, we compared EEG source imaging (ESI) solutions with a targeted density and HD-EEG montage.

Methods: HD-EEGs from patients undergoing presurgical evaluation were analyzed. A low-density recording was created by selecting the 25 electrodes of a standard montage from the 83 electrodes of the HD-EEG and adding 8-11 electrodes around the electrode with the highest amplitude interictal epileptiform discharges. The ESI solution from this "targeted" montage was compared to that from the HD-EEG using the distance between peak vertices, sublobar concordance and a qualitative similarity measure.

Results: Fifty-eight foci of forty-three patients were included. The median distance between the peak vertices of the two montages was 13.2 mm, irrespective of focus' location. Tangential generators (n = 5/58) showed a higher distance than radial generators (p = 0.04). We found sublobar concordance in 54/58 of the foci (93%). Map similarity, assessed by an epileptologist, had a median score of 4/5.

Conclusions: ESI solutions obtained from a targeted density montage show high concordance with those calculated from HD-EEG.

Significance: Requiring significantly fewer electrodes, targeted density EEG allows obtaining similar ESI solutions as traditional HD-EEG montage.





BookR developed by Sriram Narayanan
for the Concordia University School of Health
Copyright © 2011-2026
Cookie settings
Concordia University