Keyword search (4,164 papers available)

"Tandem mass spectrometry" Keyword-tagged Publications:

Title Authors PubMed ID
1 Detection of Fusobacterium nucleatum subspecies in the saliva of pre-colorectal cancer patients, using tandem mass spectrometry Morsi H; Golizeh M; Brosseau N; Janati AI; Emami E; Ndao M; Tran SD; 34929558
BIOLOGY
2 A threshold LC-MS/MS method for 92 analytes in oral fluid collected with the Quantisal® device Desharnais B; Lajoie MJ; Laquerre J; Mireault P; Skinner CD; 33035929
CHEMBIOCHEM

 

Title:A threshold LC-MS/MS method for 92 analytes in oral fluid collected with the Quantisal® device
Authors:Desharnais BLajoie MJLaquerre JMireault PSkinner CD
Link:https://pubmed.ncbi.nlm.nih.gov/33035929/
DOI:10.1016/j.forsciint.2020.110506
Publication:Forensic science international
Keywords:Liquid chromatography tandem mass spectrometryOral fluidQualitative decision point methodsQuantisalRoadside surveySaliva
PMID:33035929 Category:Forensic Sci Int Date Added:2020-10-10
Dept Affiliation: CHEMBIOCHEM
1 Laboratoire de sciences judiciaires et de médecine légale, Department of Toxicology, 1701 Parthenais Street, Montréal, Québec, H2K 3S7, Canada; Concordia University, Department of Chemistry & Biochemistry, 7141 Sherbrooke Street West, Montréal, Québec, H4B 1R6, Canada. Electronic address: brigitte.desharnais@msp.gouv.qc.ca.
2 Laboratoire de sciences judiciaires et de médecine légale, Department of Toxicology, 1701 Parthenais Street, Montréal, Québec, H2K 3S7, Canada.
3 Concordia University, Department of Chemistry & Biochemistry, 7141 Sherbrooke Street West, Montréal, Québec, H4B 1R6, Canada.

Description:

A study of impaired driving rates in the province of Québec is currently planned following the legalization of recreational cannabis in Canada. Oral fluid (OF) samples are to be collected with a Quantisal® device and sent to the laboratory for analysis. In order to prepare for this project, a qualitative decision point analysis method monitoring for the presence of 97 drugs and metabolites in OF was developed and validated. This high throughput method uses incubation with a precipitation solvent (acetone:acetonitrile 30:70 v:v) to boost drug recovery from the collecting device and improve stability of benzodiazepines (e.g., a-hydroxyalprazolam, clonazepam, 7-aminoclonazepam, flunitrazepam, 7-aminoflunitrazepam, N-desmethylflunitrazepam, nitrazepam). The Quantisal® device has polyglycol in its stabilizing buffer, but timed use of the mass spectrometer waste valve proved sufficient to avoid the glycol interferences for nearly all analytes. Interferences from OF matrices and 140 potentially interfering compounds, carryover, ion ratios, stability, recovery, reproducibility, robustness, false positive rate, false negative rate, selectivity, sensitivity and reliability rates were tested in the validation process. Five of the targeted analytes (olanzapine, oxazepam, 7-aminoclonazepam, flunitrazepam and nitrazepam) did not meet the set validation criteria but will be monitored for identification purposes (no comparison to a cut-off level). Blind internal proficiency testing was performed, where six OF samples were tested and analytes were classified as "negative", "likely positive" or "positive" with success. The final validated OF qualitative decision point method covers 92 analytes, and the presence of 5 additional analytes is screened in this high throughput analysis.





BookR developed by Sriram Narayanan
for the Concordia University School of Health
Copyright © 2011-2026
Cookie settings
Concordia University