| Keyword search (4,163 papers available) | ![]() |
"Ren C" Authored Publications:
| Title | Authors | PubMed ID | |
|---|---|---|---|
| 1 | A practical approach for preventing dispersion of infection disease in naturally ventilated room | Ren C; Cao SJ; Haghighat F; | 40477856 ENCS |
| 2 | Refined design of ventilation systems to mitigate infection risk in hospital wards: Perspective from ventilation openings setting | Ren C; Wang J; Feng Z; Kim MK; Haghighat F; Cao SJ; | 37336354 ENCS |
| 3 | Intelligent operation, maintenance, and control system for public building: Towards infection risk mitigation and energy efficiency | Ren C; Zhu HC; Wang J; Feng Z; Chen G; Haghighat F; Cao SJ; | 36941886 ENCS |
| 4 | Impact of ionizers on prevention of airborne infection in classroom | Ren C; Haghighat F; Feng Z; Kumar P; Cao SJ; | 36474607 ENCS |
| 5 | Mitigating COVID-19 infection disease transmission in indoor environment using physical barriers | Ren C; Xi C; Wang J; Feng Z; Nasiri F; Cao SJ; Haghighat F; | 34306996 ENCS |
| Title: | Refined design of ventilation systems to mitigate infection risk in hospital wards: Perspective from ventilation openings setting | ||||
| Authors: | Ren C, Wang J, Feng Z, Kim MK, Haghighat F, Cao SJ | ||||
| Link: | https://pubmed.ncbi.nlm.nih.gov/37336354/ | ||||
| DOI: | 10.1016/j.envpol.2023.122025 | ||||
| Publication: | Environmental pollution (Barking, Essex : 1987) | ||||
| Keywords: | Hospital ward; Infected patient; Infection risk; Pollutant removal; Refined ventilation system design; Ventilation openings; | ||||
| PMID: | 37336354 | Category: | Date Added: | 2023-06-20 | |
| Dept Affiliation: | ENCS | ||||
Description: |
To prevent respiratory infections between patients and medical workers, the transmission risk of airborne pollutants in hospital wards must be mitigated. The ventilation modes, which are regarded as an important strategy to minimize the infection risk, is challenging to systematically design. Studies have considered the effect of ventilation openings (inlets/outlets) or infected source locations on the airflow distribution, pollutant removal, and infection risk mitigation. However, the relationship (such as relative distance) between ventilation openings and infected sources is critical because it affects the direct exhaust of exhaled pollutants, which has not been thoroughly studied. To explore pollutant removal and infection prevention in wards, different ventilation modes (with varying ventilation openings) and infected patient locations must be jointly considered. This study investigated displacement ventilation (DV), downward ventilation (DWV), and stratum ventilation (SV) with 4, 6, and 10 scenarios of ventilation openings, respectively. The optimal ventilation mode and relative distance between outlets and infected patients were analyzed based on the simulated pollutant concentration fields and the evaluated infection risk. The pollutant removal effect and infection risk mitigation of SV in the ward were largely improved by 67% and 59% compared with DV and DWV, respectively. The average infection risk was reduced below 7% when a non-dimensional relative distance (a ratio of the actual distance to the cubic root of the ward volume) was less than 0.25 between outlets and infected patient. This study can serve as a guide for the systematic ventilation system design in hospitals during the epidemic. |