Keyword search (4,163 papers available)

"Lina JM" Authored Publications:

Title Authors PubMed ID
1 How vigilance states influence source imaging of physiological brain oscillations: evidence from intracranial EEG Wei X; Afnan J; Avigdor T; von Ellenrieder N; Delaire É; Royer J; Ho A; Minato E; Schiller K; Jaber K; Wang YL; Moye M; Bernhardt BC; Lina JM; Grova C; Frauscher B; 41687693
SOH
2 Hemodynamic correlates of fluctuations in neuronal excitability: A simultaneous Paired Associative Stimulation (PAS) and functional near infra-red spectroscopy (fNIRS) study Cai Z; Pellegrino G; Spilkin A; Delaire E; Uji M; Abdallah C; Lina JM; Fecteau S; Grova C; 40567300
PERFORM
3 NIRSTORM: a Brainstorm extension dedicated to functional near-infrared spectroscopy data analysis, advanced 3D reconstructions, and optimal probe design Delaire É; Vincent T; Cai Z; Machado A; Hugueville L; Schwartz D; Tadel F; Cassani R; Bherer L; Lina JM; Pélégrini-Issac M; Grova C; 40375973
SOH
4 EEG/MEG source imaging of deep brain activity within the maximum entropy on the mean framework: Simulations and validation in epilepsy Afnan J; Cai Z; Lina JM; Abdallah C; Delaire E; Avigdor T; Ros V; Hedrich T; von Ellenrieder N; Kobayashi E; Frauscher B; Gotman J; Grova C; 38994740
SOH
5 Validating MEG source imaging of resting state oscillatory patterns with an intracranial EEG atlas Afnan J; von Ellenrieder N; Lina JM; Pellegrino G; Arcara G; Cai Z; Hedrich T; Abdallah C; Khajehpour H; Frauscher B; Gotman J; Grova C; 37149236
PERFORM
6 Hierarchical Bayesian modeling of the relationship between task-related hemodynamic responses and cortical excitability Cai Z; Pellegrino G; Lina JM; Benali H; Grova C; 36250709
PERFORM
7 Evaluation of a personalized functional near infra-red optical tomography workflow using maximum entropy on the mean Cai Z; Uji M; Aydin Ü; Pellegrino G; Spilkin A; Delaire É; Abdallah C; Lina JM; Grova C; 34342073
PERFORM
8 Data-driven beamforming technique to attenuate ballistocardiogram artefacts in electroencephalography-functional magnetic resonance imaging without detecting cardiac pulses in electrocardiography recordings Uji M; Cross N; Pomares FB; Perrault AA; Jegou A; Nguyen A; Aydin U; Lina JM; Dang-Vu TT; Grova C; 34101939
PERFORM
9 How cerebral cortex protects itself from interictal spikes: The alpha/beta inhibition mechanism Pellegrino G; Hedrich T; Sziklas V; Lina JM; Grova C; Kobayashi E; 34002916
PERFORM
10 Deconvolution of hemodynamic responses along the cortical surface using personalized functional near infrared spectroscopy Machado A; Cai Z; Vincent T; Pellegrino G; Lina JM; Kobayashi E; Grova C; 33727581
PERFORM
11 Effects of Independent Component Analysis on Magnetoencephalography Source Localization in Pre-surgical Frontal Lobe Epilepsy Patients Pellegrino G, Xu M, Alkuwaiti A, Porras-Bettancourt M, Abbas G, Lina JM, Grova C, Kobayashi E, 32582009
PERFORM
12 Accuracy and spatial properties of distributed magnetic source imaging techniques in the investigation of focal epilepsy patients. Pellegrino G, Hedrich T, Porras-Bettancourt M, Lina JM, Aydin Ü, Hall J, Grova C, Kobayashi E 32386115
PERFORM
13 Magnetoencephalography resting state connectivity patterns as indicatives of surgical outcome in epilepsy patients. Aydin Ü, Pellegrino G, Bin Ka'b Ali O, Abdallah C, Dubeau F, Lina JM, Kobayashi E, Grova C 32191632
PERFORM
14 Differences in MEG and EEG power-law scaling explained by a coupling between spatial coherence and frequency: a simulation study. Bénar CG, Grova C, Jirsa VK, Lina JM 31292816
PERFORM
15 Localization Accuracy of Distributed Inverse Solutions for Electric and Magnetic Source Imaging of Interictal Epileptic Discharges in Patients with Focal Epilepsy. Heers M, Chowdhury RA, Hedrich T, Dubeau F, Hall JA, Lina JM, Grova C, Kobayashi E 25609211
PERFORM
16 MEG-EEG Information Fusion and Electromagnetic Source Imaging: From Theory to Clinical Application in Epilepsy. Chowdhury RA, Zerouali Y, Hedrich T, Heers M, Kobayashi E, Lina JM, Grova C 26016950
PERFORM
17 Detection and Magnetic Source Imaging of Fast Oscillations (40-160 Hz) Recorded with Magnetoencephalography in Focal Epilepsy Patients. von Ellenrieder N, Pellegrino G, Hedrich T, Gotman J, Lina JM, Grova C, Kobayashi E 26830767
PERFORM
18 Intracranial EEG potentials estimated from MEG sources: A new approach to correlate MEG and iEEG data in epilepsy. Grova C, Aiguabella M, Zelmann R, Lina JM, Hall JA, Kobayashi E 26931511
PERFORM
19 SPARK: Sparsity-based analysis of reliable k-hubness and overlapping network structure in brain functional connectivity. Lee K, Lina JM, Gotman J, Grova C 27046111
PERFORM
20 Source localization of the seizure onset zone from ictal EEG/MEG data. Pellegrino G, Hedrich T, Chowdhury R, Hall JA, Lina JM, Dubeau F, Kobayashi E, Grova C 27059157
PERFORM
21 Clinical yield of magnetoencephalography distributed source imaging in epilepsy: A comparison with equivalent current dipole method. Pellegrino G, Hedrich T, Chowdhury RA, Hall JA, Dubeau F, Lina JM, Kobayashi E, Grova C 29024165
PERFORM
22 Reproducibility of EEG-MEG fusion source analysis of interictal spikes: Relevance in presurgical evaluation of epilepsy. Chowdhury RA, Pellegrino G, Aydin Ü, Lina JM, Dubeau F, Kobayashi E, Grova C 29164737
PERFORM
23 Disruption, emergence and lateralization of brain network hubs in mesial temporal lobe epilepsy. Lee K, Khoo HM, Lina JM, Dubeau F, Gotman J, Grova C 30094158
PERFORM
24 Optimal positioning of optodes on the scalp for personalized functional near-infrared spectroscopy investigations. Machado A, Cai Z, Pellegrino G, Marcotte O, Vincent T, Lina JM, Kobayashi E, Grova C 30107210
PERFORM
25 Complex patterns of spatially extended generators of epileptic activity: Comparison of source localization methods cMEM and 4-ExSo-MUSIC on high resolution EEG and MEG data. Chowdhury RA, Merlet I, Birot G, Kobayashi E, Nica A, Biraben A, Wendling F, Lina JM, Albera L, Grova C 27561712
PERFORM
26 Comparison of the spatial resolution of source imaging techniques in high-density EEG and MEG. Hedrich T, Pellegrino G, Kobayashi E, Lina JM, Grova C 28619655
PERFORM
27 Beyond spindles: interactions between sleep spindles and boundary frequencies during cued reactivation of motor memory representations. Laventure S, Pinsard B, Lungu O, Carrier J, Fogel S, Benali H, Lina JM, Boutin A, Doyon J 30137521
PERFORM

 

Title:Clinical yield of magnetoencephalography distributed source imaging in epilepsy: A comparison with equivalent current dipole method.
Authors:Pellegrino GHedrich TChowdhury RAHall JADubeau FLina JMKobayashi EGrova C
Link:https://www.ncbi.nlm.nih.gov/pubmed/29024165?dopt=Abstract
DOI:10.1002/hbm.23837
Publication:Human brain mapping
Keywords:MEGdipoledistributed sourceinterictal epileptiform dischargesmagnetic source imagingpresurgical evaluationsource localizationspikesurgery
PMID:29024165 Category:Hum Brain Mapp Date Added:2019-06-04
Dept Affiliation: PERFORM
1 Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montreal, Quebec, Canada.
2 Neurology and Neurosurgery Department, Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada.
3 IRCCS Fondazione San Camillo Hospital, Venice, Italy.
4 Departement de Génie Electrique, Ecole de Technologie Supérieure, Montreal, Quebec, Canada.
5 Centre De Recherches En Mathématiques, Montreal, Quebec, Canada.
6 Centre D'études Avancées En Médecine Du Sommeil, Centre De Recherche De L'hôpital Sacré-Coeur De Montréal, Montreal, Quebec, Canada.
7 Physics Department and PERFORM Centre, Concordia University, Montreal, Quebec, Canada.

Description:

Clinical yield of magnetoencephalography distributed source imaging in epilepsy: A comparison with equivalent current dipole method.

Hum Brain Mapp. 2018 01;39(1):218-231

Authors: Pellegrino G, Hedrich T, Chowdhury RA, Hall JA, Dubeau F, Lina JM, Kobayashi E, Grova C

Abstract

OBJECTIVE: Source localization of interictal epileptic discharges (IEDs) is clinically useful in the presurgical workup of epilepsy patients. It is usually obtained by equivalent current dipole (ECD) which localizes a point source and is the only inverse solution approved by clinical guidelines. In contrast, magnetic source imaging using distributed methods (dMSI) provides maps of the location and the extent of the generators, but its yield has not been clinically validated. We systematically compared ECD versus dMSI performed using coherent Maximum Entropy on the Mean (cMEM), a method sensitive to the spatial extent of the generators.

METHODS: 340 source localizations of IEDs derived from 49 focal epilepsy patients with foci well-defined through intracranial EEG, MRI lesions, and surgery were analyzed. The comparison was based on the assessment of the sublobar concordance with the focus and of the distance between the source and the focus.

RESULTS: dMSI sublobar concordance was significantly higher than ECD (81% vs 69%, P?<?0.001), especially for extratemporal lobe sources (dMSI?=?84%; ECD?=?67%, P?<?0.001) and for seizure free patients (dMSI?=?83%; ECD?=?70%, P?<?0.001). The median distance from the focus was 4.88 mm for ECD and 3.44 mm for dMSI (P?<?0.001). ECD dipoles were often wrongly localized in deep brain regions.

CONCLUSIONS: dMSI using cMEM exhibited better accuracy. dMSI also offered the advantage of recovering more realistic maps of the generator, which could be exploited for neuronavigation aimed at targeting invasive EEG and surgical resection. Therefore, dMSI may be preferred to ECD in clinical practice. Hum Brain Mapp 39:218-231, 2018. © 2017 Wiley Periodicals, Inc.

PMID: 29024165 [PubMed - indexed for MEDLINE]





BookR developed by Sriram Narayanan
for the Concordia University School of Health
Copyright © 2011-2026
Cookie settings
Concordia University